Evaluation of different Jaipur foot–ankle assemblies using infrared thermography

1. Andrysek, J. Lower-limb prosthetic technologies in the developing world: a review of literature from 1994–2010. Prosthet Orthot Int 2010; 34: 378–398.
Google Scholar | SAGE Journals | ISI2. Huber, I, Fischenich, KM, Wolynski, J, et al. Epidemiological study of failures of the Jaipur foot. Disabil Rehabil Assist Technol 2018; 13: 740–744.
Google Scholar | Crossref | Medline3. Olaya Mira, N, Viloria Barragán, C. Development of a protocol for the evaluation of the mechanical behavior of a transtibial prosthesis by infrared thermography. In: IFMBE proceedings, Cancún, Mexico, , pp. 805–811. Berlin: Springer.
Google Scholar4. Bougherara, H, Rahim, E, Shah, S, et al. A preliminary biomechanical assessment of a polymer composite hip implant using an infrared thermography technique validated by strain gage measurements. J Biomech Eng 2011; 133: 074503.
Google Scholar | Crossref | Medline5. Cutti, AG, Perego, P, Fusca, MC, et al. Assessment of lower limb prosthesis through wearable sensors and thermography. Sensors 2014; 14: 5041–5055.
Google Scholar | Crossref6. Prochazka, R, Dzugan, J, Konopik, P. Fatigue limit evaluation of structure materials based on thermographic analysis. Procedia Struct Integr 2017; 7: 315–320.
Google Scholar | Crossref7. Bagavathiappan, S, Lahiri, BB, Saravanan, T, et al. Infrared thermography for condition monitoring—a review. Infrared Phys Technol 2013; 60: 35–55.
Google Scholar | Crossref | ISI8. Usamentiaga, R, Garcia, DF. Infrared thermography sensor for temperature and speed measurement of moving material. Sensors 2017; 17: 1157.
Google Scholar9. Shah, S, Bougherara, H, Schemitsch, EH, et al. Biomechanical stress maps of an artificial femur obtained using a new infrared thermography technique validated by strain gages. Med Eng Phys 2012; 34: 1496–1502.
Google Scholar | Crossref | Medline | ISI10. Hayabusa, K, Inaba, K, Ikeda, H, et al. Estimation of fatigue limits from temperature data measured by IR thermography. Exp Mech 2017; 57: 185–194.
Google Scholar | Crossref11. Zanetti, EM, Musso, SS, Audenino, AL. Thermoelastic stress analysis by means of a standard thermocamera. Exp Tech 2007; 31: 42–50.
Google Scholar | Crossref | ISI12. Wang, M, Liao, Y, Chen, D. Study on the thermal effects of rubbers during loading-unloading cycles by infrared thermography. Polym Bull 2013; 70: 171–180.
Google Scholar | Crossref13. Delpueyo, D, Balandraud, X, Grédiac, M, et al. Measurement of mechanical dissipation in SMAs by infrared thermography. In: Quinn, S, Balandraud, X (eds) Residual stress, thermomechanics & infrared imaging, hybrid techniques and inverse problems, vol. 9. Berlin: Springer, 2016, pp. 9–14.
Google Scholar14. Chrysochoos, A. Infrared thermography applied to the analysis of material behavior: a brief overview. Quant Infrared Thermogr J 2012; 9: 193–208.
Google Scholar | Crossref15. Cagle, JC, Reinhall, PG, Allyn, KJ, et al. A finite element model to assess transtibial prosthetic sockets with elastomeric liners. Med Biol Eng Comput 2018; 56: 1227–1240.