Aldosari, AMA . 2014. Does steam autoclaving affect the accuracy of implant impression systems? J Biomater Tissue Eng. 4:550–554.
Google Scholar |
Crossref
Alikhasi, M, Bassir, SH, Naini, RB. 2013. Effect of multiple use of impression copings on the accuracy of implant transfer. Int J Oral Maxillofac Implants. 28(2):408–414.
Google Scholar |
Crossref |
Medline |
ISI
Almehmadi, A . 2021. An in vitro analysis of sodium hypochlorite decontamination for the reuse of implant healing abutments? J Oral Implantol. 47:271–279.
Google Scholar |
Crossref |
Medline
Baier, RE, Meyer, AE, Akers, CK, Natiella, JR, Meenaghan, M, Carter, JM. 1982. Degradative effects of conventional steam sterilization on biomaterial surfaces. Biomaterials. 3(4):241–245.
Google Scholar |
Crossref |
Medline
Barreiros, P, Braga, J, Faria-Almeida, R, Coelho, C, Teughels, W, Souza, JCM. 2021. Remnant oral biofilm and microorganisms after autoclaving sterilization of retrieved healing abutments. J Periodontal Res. 56(2):415–422.
Google Scholar |
Crossref |
Medline
Bidra, AS, Kejriwal, S, Bhuse, K. 2020. Should healing abutments and cover screws for dental implants be reused? A systematic review. J Prosthodont. 29(1):42–48.
Google Scholar |
Crossref |
Medline
Bousquet, P, Bennasar, IC, Tramini, P, Jacquemot, M, Cuisinier, F. 2014. Tightening of healing abutments: influence of torque on bacterial proliferation risk, an in vitro investigation. Biomed Tech (Berl). 2014;59(6):495–500.
Google Scholar |
Crossref |
Medline
Browne, V, Flewelling, M, Wierenga, M, Wilson, A, Aprecio, R, Richardson, P, Angelov, N, Johnson, N. 2012. Sterilization analysis of contaminated healing abutments and impression copings.J Calif Dent Assoc. 40(5):419–421.
Google Scholar |
Medline
Cain, JR, Mitchell, DL, Gillespie, JC. 2000. Sterilization of reusable implant components: a pilot study. J Prosthet Dent. 84(6):608–611.
Google Scholar |
Crossref |
Medline
Cakan, U, Delilbasi, C, Er, S, Kivanc, M. 2015. Is it safe to reuse dental implant healing abutments sterilized and serviced by dealers of dental implant manufacturers? An in vitro sterility analysis. Implant Dent. 24(2):174–179.
Google Scholar |
Medline
Canullo, L, Penarrocha-Oltra, D, Marchionni, S, Bagan, L, Penarrocha-Diago, MA, Micarelli, C. 2014. Soft tissue cell adhesion to titanium abutments after different cleaning procedures: preliminary results of a randomized clinical trial. Med Oral Patol Oral Cir Bucal. 19(2):e177–e183.
Google Scholar |
Crossref |
Medline
Chew, M, Tompkins, G, Tawse-Smith, A, Wadell, NJ, Ma, S. 2018. Reusing titanium healing abutments: comparison of two decontamination methods. Int J Prosthodont. 31(6):613–618.
Google Scholar |
Crossref |
Medline
Darvell, BW, Samman, N, Luk, WE, Clark, RK, Tiderman, H. 1995. Contamination of titanium castings by aluminum oxide blasting. J Dent. 1995;23(5):319–322.
Google Scholar |
Crossref |
Medline
Dunn, D . 2002. Reprocessing single-use devices: the ethical dilemma. AORN J. 75(5):989–999.
Google Scholar |
Crossref |
Medline
Glossary of Prosthodontic Terms: Ninth Edition . 2017. J Prosthet Dent. 117(5S):e1–e105.
Google Scholar |
Crossref |
Medline
Higgins, JPT, Thomas, J, Chandler, J, Cumpston, M, Li, T, Page, MJ, Welch, VA, editors. 2019. Cochrane handbook for systematic reviews of interventions. 2nd ed. Chichester (UK): John Wiley.
Google Scholar |
Crossref
Jain, SS, Schramm, STJ, Siddiqui, DA, Huo, W, Palmer, KL, Wilson, TG, et al 2020. Effects of multiple implantations of titanium healing abutments: surface characteristics and microbial colonization. Dent Mater. 36(9):e279–e291.
Google Scholar |
Crossref |
Medline
Jain, SS, Siddiqui, DA, Wheelis, SE, Palmer, KL, Wilson, TG, Rodrigues, DC. 2021. Mammalian cell response and bacterial adhesion on titanium healing abutments: effect of multiple implantation and sterilization cycles. Clin Oral Investig. 2021;25(5):2633–2644.
Google Scholar |
Crossref |
Medline
Kyaw, TT, Nakata, H, Takayuki, M, Kuroda, S, Kasugai, S. 2020. Evaluation of residual contamination on healing abutments after cleaning with a protein-denaturing agent and detergent. Quintessence Int. 2020;51(6):474–485.
Google Scholar |
Medline
Lausmaa, J, Kasemo, B, Hanssen, S. 1985. Accelerated growth on titanium implants during autoclaving caused by fluorine contamination. Biomaterials. 6(1):23–27.
Google Scholar |
Crossref |
Medline
Matsuyama, T, Aoki, A, Oda, S, Yoneyama, T, Ishikawa, I. 2003. Effects of the Er: YAG laser irradiation on titanium implant materials and contaminated implant abutment surfaces.J Clin Laser Med Surg. 21(1):7–17.
Google Scholar |
Crossref |
Medline
Narvekar, A, Valverde Estepa, A, Naqvi, A, Nares, S. 2020. Used dental implant healing abutments elicit immune responses: a comparative analysis of detoxification strategies. Clin Implant Dent Relat Res. 2020;22(6):730–738.
Google Scholar |
Crossref |
Medline
Noronha Oliveira, M, Schunemann, WVH, Mathew, MT, Henriques, B, Magini, RS, Teughels, W, Souza, JCM. 2018. Can degradation products released from dental implants affect peri-implant tissues? J Periodontal Res. 2018;53(1):1–11.
Google Scholar |
Crossref |
Medline
Ntrouka, V, Hoogenkamp, M, Zaura, E, van der Weijden, F. 2011. The effect of chemotherapeutic agents on titanium-adherent biofilms. Clin Oral Implants Res. 2011;22(11):1227–1234.
Google Scholar |
Crossref |
Medline
Sahin, SC, Dere, KA. 2021. Evaluation of residual contamination on reused healing abutments. Clin Oral Investig. 2021;25:5889–5895.
Google Scholar |
Crossref |
Medline
Sánchez-Garcés, MA, Jorba, M, Ciurana, J, Vinas, M, Vinuesa, MT. 2019. Is the re-use of sterilized implant abutments safe enough? (Implant abutment safety). Med Oral Patol Oral Cir Bucal. 24(5):e583–e587.
Google Scholar |
Medline
Schwartz, Z, Lohmann, CH, Blau, G, Blanchard, CR, Soskolne, AW, Liu, Y, Cochran, DL, Dean, DD, Boyan, BD. 2000. Re-use of implant coverscrews changes their surface properties but not clinical outcome. Clin Oral Implants Res. 11(3):183–194.
Google Scholar |
Crossref |
Medline
Sennerby, L, Lekholm, U. 1993. The soft tissue response to titanium abutments retrieved from humans and reimplanted in rats: a light microscopic pilot study. Int J Oral Maxillofac Surg. 1993;4(1):23–27.
Google Scholar
Shamseer, L, Moher, D, Clarke, M, Ghersi, D, Liberati, A, Petticrew, M, Shekelle, P, Stewart, LA; PRISMA-P Group . 2015. Preferred reporting items for systematic review and meta-analysis protocols (PRISMA-P) 2015: elaboration and explanation. BMJ. 2015;350:g7647.
Google Scholar |
Crossref |
Medline
Sirona Implants . 2017. Cleaning and sterilization instructions for Astra Tech Implant System® EV Dentsply Sirona Implants [accessed 2021 Aug 21].
https://assets.dentsplysirona.com/dentsply/pim/manufacturer/Implants/ Implant_systems/Astra_Tech_Implant_System_EV/Instruments/Accessories/32671332-USX 1711%20Cleaning%20and%20sterilization%20instructions%20for%20Astra%20Tech%20Implant%20System%20EV_LR.pdf
Google Scholar
Souza, JC, Henriques, M, Oliveira, R, Teughels, W, Celis, JP, Rocha, LA. 2010. Biofilms inducing ultra-low friction on titanium. J Dent Res. 89(12):1470–1475.
Google Scholar |
SAGE Journals |
ISI
Stacchi, C, Berton, F, Porrelli, D, Lombardi, T. 2018. Reuse of Implant healing abutments: comparative evaluation of the efficacy of two cleaning procedures. Int J Prosthodont. 2018;31(2):161–162.
Google Scholar |
Crossref |
Medline
Stanford, CM, Solursh, M, Keller, JC. 1994. Bone cell expression on titanium surfaces is altered by sterilization treatments. J Dent Res. 73(5):1061–1071.
Google Scholar |
SAGE Journals |
ISI
Vezeau, JP, Keller, JC, Wightman, JP. 2000. Reuse of healing abutments: an in vitro model of plasma cleaning and common sterilization techniques. Implant Dent. 2000;9(3):236–246.
Google Scholar |
Crossref
Vezeau, JP, Koorbusch, GF, Draughn, RA, Keller, JC. 1996. Effects of multiple sterilization on surface characteristics and in vitro biologic responses to titanium. J Oral Maxillofac Surg. 1996;54(6):738–746.
Google Scholar |
Crossref |
Medline
Wadhwani, C, Schonnenbaum, TR, Audia, F, Audiahung, KH. 2016. In-vitro study of the contamination remaining on used healing abutments after cleaning and sterilizing in dental practice. Clinical Impl Dent Relat Res. 2016;18(6):1069–1074.
Google Scholar |
Crossref |
Medline
Wälivaara, B, Aronsson, BO, Rodahl, M, Lausmaa, J, Tengvall, P. 1994. Titanium with different oxides. In vitro studies on protein adsorption and contact activation. Biomaterials. 1994;15(10):827–834.
Google Scholar |
Crossref |
Medline
Wheelis, SE, Wilson, TG, Valderrama, P, Rodrigues, DC. 2018. Surface characterization of titanium implant healing abutments before and after placement. Clin Implant Dent Relat Res. 2018;20(2):180–190.
Google Scholar |
Crossref |
Medline
Youngblood, T, Ong, JL. 2003. Effect of plasma-glow discharge as a sterilization of titanium surfaces. Implant Dent. 2003;12(1):54–60.
Google Scholar |
Crossref |
Medline
Comments (0)