Routine surveillance of kidney allograft rejection using a fully automated urinary CXCL9 and CXCL10 immunoassay

Abstract

Background For kidney transplant recipients, assessing non-invasively the individualized risk of acute rejection is one of the most unmet need. Urinary chemokines are one of the short-term most promising biomarkers, because of their simple and low-cost analytical method in easily accessible samples, and their high diagnostic performance consistently assessed over the last decade. In this study, we aimed at confronting all practical issues of routine implementation of kidney allograft rejection monitoring using urine CXCL9 and CXCL10. Methods The next-generation immunoassay Ella® was investigated as feasible quantification platform, from sample collection to render of the results. Urine CXCL9/10 levels were measured using Ella® microfluidic cartridges, across preanalytical (sample preparation, storage conditions, freeze-thaw cycles) and analytical (linearity, ranges, intra/inter-assay variability) performances studies, and diagnostic accuracy was assessed in comparison to the ELISA reference method, in urine samples from previously published cohorts. Results Upon assay preparation, Ella® appeared very efficient with a minimal workflow (urine sample thaw> centrifugation>1:2 dilution>loading) and a time to result of 90 minutes. Preanalytical studies showed high stability of urine CXCL9/10 levels across various temperatures (4° vs 25°C) and time (24/48/72H) before storage and over 5 freeze-thaw cycles. How complex urine matrix, analytical studies confirmed excellent linearity of dosage, as well as intra-assay (≤5%) and inter-assay precision. Across 1024 samples, Ella® results were highly correlated to those quantified by ELISA (P<0.0001), and further entered into our previously validated urine chemokine model. 268 out of the 1024 samples were collected at time of acute rejection (26.2%). In this cohort, accuracy was 0.85 for acute rejection diagnosis. Conclusion Ella® fulfils all prerequisites for clinical implementation of urinary chemokines monitoring. It has proven a robust, easy-to-use platform with unprecedented validation to quantify urine chemokines.

Competing Interest Statement

The authors have declared no competing interest.

Funding Statement

The Emmanuel Boussard Foundation supported DA, LA, CT and VS, and DA received funds from the Day Solvay Foundation.

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

Ethics Committee of Ile-de-France XI (#13016)

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.

Yes

Data Availability

The data that support the findings of this study are available from the corresponding author upon reasonable request.

留言 (0)

沒有登入
gif