The metallic mold was placed on a glass slide covered with a celluloid strip and filled with the test materials, following the manufacturer’s instructions. All of the materials were immediately covered with a new celluloid strip, followed by the glass slide, and pressed with a 200-g stainless steel standard weight for seven minutes to enable the early setting reaction. In the coated subgroups, the surfaces of each specimen (top, bottom, and sides) had one layer of G-Coat Plus (GF, GM, and GU subgroups) or KetacTM Glaze (KF, KM, and KU subgroups), which were applied using a disposable brush, according to the materials’ instructions. The celluloid strip was gently pressed, after which the specimen was light cured for 20 s per side using an LED curing light. The exclusion criteria were as follows: specimens with a void, a rough surface, or a surface coating thickness of more than 0.05 mm. All of the prepared specimens were submerged in individually sealed plastic vials containing 5 mL of deionized water and put in a 37 °C incubator.
The potentiometric method, which follows ISO19448-2018 [33], was performed to measure the concentrations of the released and recharged fluoride ions by using a fluoride ion-specific electrode (Orion™ 9157BNMD Triode™ 3-in-1 pH/ATC probe, Thermo Fisher Scientific Inc., Waltham, MA, USA) connected to a digital pH/ISE meter (Orion™ Versa Star Pro™, Thermo Fisher Scientific Inc., Waltham, MA, USA). The electrode was calibrated with standard fluoride solutions of 0.1, 1, 10, and 100 parts per million (ppm) mixed with a total ionic strength adjustment buffer (TISAB II with CDTA, Orion 940909, Thermo Fisher Scientific Inc., Waltham, MA, USA). Each specimen solution was prepared by pipetting 1 mL of deionized water from each specimen vial, which was then buffered with 1 mL of TISAB II. The fluoride concentration (ppm) was measured at 24 h and at weeks 1, 2, 3, and 4 of immersion.After measuring the fluoride release for 4 weeks, all of the specimens were used to study the fluoride recharge ability. In this study, 1.23% APF gels were used for recharging the fluoride ions. Each specimen was immersed in a plastic vial containing 5 mL of the 1.23% acidulated phosphate fluoride (APF) gel for 4 min, after which the excess gel was removed by wiping it with gauze. All of the discs were left undisturbed for 30 min, after which they were washed with 50 mL of deionized water and put on an absorbent paper for 2 min to dry them. The measurement of the recharged fluoride ions was performed at the same time intervals as the fluoride release days, which were at 24 h, 1, 2, 3, and 4 weeks, respectively. After measuring the recharged fluoride at each time point, the specimens were rinsed with 50 mL of deionized water, dried on absorbent paper for 2 min, and transferred to a new, individually sealed plastic vial containing 5 mL of fresh deionized water and stored in a 37 °C incubator.
Statistical AnalysisAll of the data were analyzed using SPSS Statistics Version 22 for Windows (IBM corp., Armonk, NY, USA). Normal distribution and variance equality tests were performed using the Kolmogorov–Smirnov and Levene’s tests, respectively. The data were normally distributed but nonhomogeneous. To determine the effects of the material types, surface coating procedures, and their interactions, a two-way ANOVA followed by a post-hoc Tamhane multiple post-hoc was performed. A one-way repeated measures ANOVA and Tamhane multiple comparison test were conducted to evaluate the effects of the immersion time points. The significance level was set at 0.05.
4. DiscussionThe amount of released and recharged fluoride ions varied among the materials [34] due to differences in the resin matrix, filler composition, solubility, and porosity of the materials [23,35,36,37]. Among all of the tested GICs, KetacTM Universal AplicapTM presented the highest fluoride release and recharge at all time points. This result agreed with a previous study, which showed that materials with a high fluoride release ability also have a high fluoride recharge ability [38].In this study, all of the specimens were prepared and tested under the same conditions by one person to eliminate human variables. However, the thickness of the coating materials, which may be one of the confounding factors, was controlled. According to the manufacturer’s fact sheet, the thickness of the G-Coat Plus coating layer is 35–40 μm. Thus, one of the exclusion criteria in this study was a coating thickness of more than 50 μm. However, no samples were excluded.
For the surface coating factor, KetacTM Glaze and G-Coat Plus significantly decreased the fluoride release and recharge in all of the test materials (KetacTM Universal AplicapTM, KetacTM Molar AplicapTM, and KetacTM Fil Plus AplicapTM) at all time points (at 24 h, 1, 2, 3, and 4 weeks). The previous studies reported that the application of a surface coating diminished the fluoride release [23,24,25,39] and recharge [24] in some HVGICs. Kelić et al. investigated the effect of a resin coating (GC Fuji COAT LC) on the fluoride release of HVGIC (Fuji IX EXTRA) at different time points: 1 h, 24 h, 2 days, 7 days, 28 days, 84 days, and 168 days. They found that the coated specimens released fluoride at a rate about thirty times lower than the uncoated specimens [23]. Additionally, Shatat reported that resin-based coatings (G-Coat Plus and Scotchbond Universal) reduced the fluoride release ability of KetacTM Molar AplicapTM, particularly during the first week [39]. Habib et al. found a dramatic reduction in the fluoride release and recharge in EQUIA Forte Fil coated with a nanofilled resin coating (EQUIA Forte Coat) [24]. This can be explained by the mechanisms of fluoride release and recharge in GICs, which consist of two parts. The first mechanism is a short-term reaction where a rapid dissolution occurs from the outer surface layer of the GICs [37,40]. The GICs dissolve several ions, such as calcium, aluminum, and fluoride ions, as the setting reaction is initiated [14]. The second mechanism is a long-term reaction where there is a slow process of fluoride ions diffusing through the bulk of the GICs into the surrounding aqueous media [37,40]. When the GIC is protected with a coating agent, the superficial layer of the immature GIC is less dissolved and, consequently, releases a smaller amount of fluoride [25]. Moreover, Shatat found that coating the GICs (KetacTM Molar AplicapTM) with a nanofilled coating (G-Coat Plus) resulted in less fluoride release than coating with an unfilled resin (Riva coat) [39]. This was probably due to the micro-mechanical interlocking between the nanofiller in the G-Coat Plus and the GICs [8,11]. Moreover, another study found that an unfilled resin coating agent (Single Bond Universal Adhesive) had no micro-mechanical interlocking with the KetacTM Molar AplicapTM and the KetacTM Universal AplicapTM in SEM images [31]. In addition, hydrolysis of the unfilled resin coating occurred consistently over time and resulted in the degradation of the unfilled resin coating component over time [41].According to the pattern of fluoride release, the highest amount of released fluoride ions occurred in the first 24 h during the initial setting reaction, called the “initial burst” [37,40]. The initial burst is important for remineralization and reducing the viability of microorganisms that may have been left in the carious dentine. After the initial burst, the fluoride release significantly decreased over the first week [42] and maintained a constant low level for 10–20 days [37]. It was reported that a small amount of fluoride is released long-term, which can last for several months to 5 years [37,40]. However, these low levels of released fluoride might be insufficient to prevent secondary caries. A fluoride concentration of at least 1 ppm is required to inhibit enamel demineralization [43]. The fluoride recharge process has the ability to take up fluoride from external sources. The capacity for fluoride recharge from external sources is very necessary to maintain the levels of fluoride [24]. The GICs act as fluoride reservoirs to increase the fluoride levels and prevent secondary caries [37].The pattern of fluoride recharge by topical fluoride was found to be similar to the intrinsic fluoride release pattern, which consisted of two parts. The first part was a short-term increase in the first 24 h, but usually not more than the initial burst [37], and the second part was a rapid decrease to nearly pre-exposure levels within the first week [44]. Karabulut et al. evaluated the recharged fluoride ions by repeating the fluoride treatments. They found that each repetition provided a rise in the recharged fluoride ions and that they decreased in a short time [45]. Previous publications found higher fluoride releases in acidic conditions [36,46]. Ghajari et al. reported that the amount of recharged fluoride was significantly higher in 1.23% APF gels when compared to 2% NaF gels [47]. From this study, the patterns of fluoride release and recharge were slightly varied among the tested GICs; the KetacTM Universal AplicapTM presented the highest fluoride release and recharge. Moreover, we found that KetacTM Universal AplicapTM maintained the highest fluoride recharge for up to one week longer than the other tested GICs.The limitations of the present study were that this was a short-duration in vitro study. The study did not completely reflect a clinical condition, which is influenced by various factors that are different from a laboratory situation. In oral conditions, factors, including masticatory force, brushing force, and changes in temperature and pH, can all interfere with the adhesion between the coating agents and GICs, which might affect the fluoride release and recharge abilities of the GICs. Further clinical studies or laboratory-designed, simulated oral conditions should be conducted. Moreover, a further long-term study (3–6 months) should be performed to evaluate the amount of fluoride. In addition, home-use fluorides, such as fluoride dentifrice and fluoride mouth rinse, which are important sources of external fluoride, should be investigated.
The clinical decisions between coated and uncoated materials depend on the purpose for which these materials are chosen. To maximize the remineralization effects, uncoated materials might be a better choice. However, maintaining oral hygiene is still an important factor to enhance remineralization and optimize fluoride reservoirs for the GICs.