The Anatomic Position of the Sciatic Nerve During Percutaneous Retrograde Posterior Column Fixation Is Determined by Hip Position

OBJECTIVES: 

There are multiple established patient positions for placement of a percutaneous retrograde posterior column screw for fixation of acetabulum fractures. The sciatic nerve is at risk of injury during this procedure because it lies adjacent to the start point at the ischial tuberosity. The purpose of this study was to define how the position of the sciatic nerve, relative to the ischial tuberosity, changes regarding the patient's hip position.

METHODS: 

In a cohort of 11 healthy volunteers, ultrasound was used to measure the absolute distance between the ischial tuberosity and the sciatic nerve. Measurements were made with the hip and knee flexed to 90 degrees to simulate supine and lateral positioning and with the hip extended to simulate prone positioning. In both positions, the hip was kept in neutral abduction and neutral rotation.

RESULTS: 

The distance from the lateral border of the ischial tuberosity to the medial border of the sciatic nerve was greater in all subjects in the hip-flexed position versus the extended position. The mean distance was 17 mm (range, 14–27 mm) in the hip-extended position and 39 mm (range, 26–56 mm) in the hip-flexed position (P < 0.001).

CONCLUSIONS: 

The sciatic nerve demonstrates marked excursion away from the ischial tuberosity when the hip is flexed compared with when it is extended. The safest patient position for percutaneous placement of a retrograde posterior column screw is lateral or supine with the hip flexed to 90 degrees.

留言 (0)

沒有登入
gif