Comparison of efficacy, safety & satisfaction of intermittent versus continuous phototherapy in hyperbilirubinaemic newborns ≥35 week gestation: A randomized controlled trial


   Table of Contents       ORIGINAL ARTICLE Year : 2021  |  Volume : 153  |  Issue : 4  |  Page : 446-452

Comparison of efficacy, safety & satisfaction of intermittent versus continuous phototherapy in hyperbilirubinaemic newborns ≥35 week gestation: A randomized controlled trial

Sasi Bhushan Gottimukkala1, Giridhar Sethuraman1, Srinivasan Kitchanan1, Surajit Pathak2
1 Department of Neonatology, Chettinad Hospital & Research Institute, Chennai, Tamil Nadu, India
2 Department of Allied Health Sciences, Chettinad Hospital & Research Institute, Chennai, Tamil Nadu, India

Date of Web Publication2-Aug-2021

Correspondence Address:
Giridhar Sethuraman
Department of Neonatology, A- Block 1st Floor, Chettinad Hospital & Research Institute, Kelambakkam, Kanchipuram, Chennai 603 103, Tamil Nadu
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None

Crossref citationsCheck

DOI: 10.4103/ijmr.IJMR_2156_18

Rights and Permissions

   Abstract 

Background & objectives: Phototherapy (PT) has become the standard of care for treating neonatal jaundice. This study was aimed to find out if intermittent PT (IPT) results in comparable rate of fall of bilirubin level to continuous PT (CPT) and results in lesser side effects and better acceptance.
Methods: In this non-inferiority trial, 174 neonates ≥35 wk gestation and >2000 g with jaundice requiring PT were randomized to receive either IPT (one hour on and two hours off) or CPT (with minimum interruptions for feeding) after device stratification [light-emitting diode (LED) or compact fluorescent light (CFL)]. Bilirubin was checked 12th hourly, and calcium, vitamin D and nitric oxide (NO) levels were analyzed along with the clinical side effects and nursing and maternal satisfaction scores (CTRI Registration No. CTRI/2018/01/011072).
Results: The rate of fall of bilirubin was similar in both the CPT and IPT groups [0.16 (0.10, 0.22) vs. 0.13 (0.09, 0.20) mg/dl/h, P=0.22]. The median difference with 95 per cent confidence interval of 0.03 (0.03, 0.03) mg/dl was also within the pre-defined inferiority limits. There was no significant change in the duration of PT and side effects such as fall in calcium levels, rise in vitamin D and NO levels or the clinical side effects. Maternal satisfaction favoured the IPT group, but the nurses opined that IPT was difficult to implement. Subgroup analysis for PT devices used showed that efficacy of both CFL and LED devices was equivalent.
Interpretation & conclusions: IPT was non-inferior to CPT in reducing bilirubin levels in ≥35 wk neonates, irrespective of device used, and also mothers reported better satisfaction with IPT. Although IPT appears promising, CPT does not increase clinical and biochemical side effects compared to IPT.

Keywords: Compact fluorescent light - continuous phototherapy - intermittent phototherapy - jaundice - light-emitting diode - neonate


How to cite this article:
Gottimukkala SB, Sethuraman G, Kitchanan S, Pathak S. Comparison of efficacy, safety & satisfaction of intermittent versus continuous phototherapy in hyperbilirubinaemic newborns ≥35 week gestation: A randomized controlled trial. Indian J Med Res 2021;153:446-52
How to cite this URL:
Gottimukkala SB, Sethuraman G, Kitchanan S, Pathak S. Comparison of efficacy, safety & satisfaction of intermittent versus continuous phototherapy in hyperbilirubinaemic newborns ≥35 week gestation: A randomized controlled trial. Indian J Med Res [serial online] 2021 [cited 2021 Aug 2];153:446-52. Available from: 
https://www.ijmr.org.in/text.asp?2021/153/4/446/322935
Neonatal hyperbilirubinaemia is a common newborn condition, which, if not identified and treated early, may result in neurological complications. Phototherapy (PT) is the current standard of care for treating neonatal jaundice. To increase effectiveness, continuous PT (CPT) is recommended which involves maintaining the jaundiced neonate under PT virtually all the time with only minimal interruptions (e.g., during feeding or cleaning). However, this often results in interference with mother–infant bonding and it impedes breastfeeding[1],[2]. PT exposure is also known to cause a few side effects, mainly due to the duration of PT exposure[3]. Notable among these are body temperature changes[4], skin rash[5], diarrhoea[6], fall in calcium levels[7], opening up of patent ductus arteriosus, especially in preterm infants, and other haemodynamic changes mainly due to increase in nitric oxide (NO) levels[8],[9],[10]. PT may increase plasma levels of vitamin D[11],[12].

Photodegradation of bilirubin is a two-step phenomenon, where the first step is the rapid photochemical reaction at the skin level, followed by the slow migration of unbound bilirubin from the blood into the skin for ongoing photodegradation over a period of 1-3 h[13],[14]. Interruptions in PT during this period potentially cause little alterations in bilirubin levels and also allow for migration of bilirubin to proceed effectively. Hence, intermittent PT (IPT) which involves regular cessation of PT at specific times and for specific duration appears to be a plausible alternative to CPT. Furthermore, lesser duration of PT exposure with IPT could potentially result in lesser side effects, allay parental anxiety and improve nursing experience. Hence, this study was conducted to determine if IPT results in comparable rate of fall of bilirubin as CPT, with better acceptance and lesser biochemical and clinical side effects.

   Material & Methods Top

A non-inferiority, open-labelled, randomized controlled trial was conducted in the neonatal intensive care unit of Chettinad Hospital and Research Institute, Chennai, India, from October 2016 to September 2017. Approval from the Human Ethics Committee (50/IHEC/6-16 dated 18 July 2016) and Clinical trials Registry of India registration (CTRI/2018/01/011072) were obtained. All neonates ≥35 wk of gestation and ≥2000 g at birth, whose serum bilirubin was at a level requiring PT, as decided by the treating clinician, were included during the study period. As per the Unit policy, a PT cut-off of 2 mg/dl less than the threshold suggested by the American Academy of Paediatrics (AAP) guidelines[15] was chosen to initiate PT in jaundiced neonates. PT was discontinued if bilirubin levels fell to <6 mg/dl on day 1, <10 mg/dl on day 2 and <13 mg/dl thereafter. Neonates needing immediate exchange transfusion, those with significant haemolytic jaundice, major congenital anomalies, birth asphyxia, significant haemodynamic instability and significant conjugated hyperbilirubinaemia and those who already received >5 h of PT were excluded.

Our earlier unit data (unpublished) showed that the mean rate of fall of bilirubin after CPT was 0.19±0.1 mg/dl/h. To prove, with 80 per cent power and an alpha error of 0.05, that the rate of fall of bilirubin with IPT was not different from CPT by ≥0.04 mg/dl/h, 77 neonates were needed to be enrolled in each group (STATA IC, Version 13, StatCorp, College Station, TX, USA). To account for an additional requirement of 15 per cent to conduct corresponding non-parametric test, the required sample size was 85 neonates in each group.

Of the 210 neonates assessed for eligibility, 36 were excluded for various reasons such as not giving consent (n=21), needing exchange (n=4), haemodynamically unstable (n=9) and conjugated hyperbilirubinaemia (n=2) and 174 were finally randomized. After informed written consent from the parents, the enrolled infants were stratified according to PT device type, compact fluorescent light (CFL) and light-emitting diode (LED). They were randomly allocated to receive either IPT or CPT. The random sequence was generated online (http://www.randomization.com) and serially numbered, opaque, sealed envelopes in block sizes of eight were prepared. The primary investigator allocated the groups by opening the identical envelopes containing the treatment code. Considering the nature of intervention, blinding was not attempted, but the laboratory technician who did the processing of the blood samples, was unaware of allocation.

All enrolled neonates received intensive PT (irradiance ≥30 μW/cm2/nm) using either CFL PT Unit [Nice Neotech (P) Ltd., Chennai, India] or Brilliance Pro LED [Phoenix Medical Systems (P) Ltd., Chennai]. A distance of 25-30 cm was maintained between the neonate and the device, and the irradiance was checked before PT using a Nice 4020 spectroradiometer [Nice Neotech (P) Ltd., Chennai] to ensure deliverance of ≥30 μW/cm2/nm. An additional bottom PT was added, if required.

IPT was defined as PT delivered in cycles of one hour on and two hours off. The two-hours off period was utilized for kangaroo care, feeding and cleaning the infant. CPT was defined as neonates receiving PT with ≤9 interruptions for feeding lasting ≤20 min over a 24 h period. The number of interruptions (both intended and otherwise) was noted, and all efforts were taken to ensure adherence to protocol. A lactation counsellor helped mothers with breastfeeding and coordinated the feed timings and ensured that the neonates were adequately fed during the break period. Nursing satisfaction was obtained at fortnightly intervals using a feedback form, a Likert-type scale developed in our Unit. The mothers scored their experience when PT was stopped, using a scale, developed by Olusanya et al[16].

Serum bilirubin levels were measured every 12 h by the Jendrassik-Grof method[17] (Coral Clinisystems, Goa, India assay sensitivity – 0.1 mg/dl). Testing was also be done for levels of NO (Griess reaction[18]: SRL Pvt Ltd, Chennai; sensitivity 500 nM/l), calcium (o-cresolphthalein complexone method[19]: Coral Clinisystems, Goa; sensitivity 2 mg/dl) and vitamin DELISA[20] (Eagle Biosciences, Nashua, NH, USA; sensitivity 0.5 ng/ml) at enrolment and immediately after study completion. External quality assurance was done with the department of Clinical Biochemistry, Christian Medical College, Vellore. The vital signs including non-invasive blood pressure were recorded at enrolment and then hourly till completion of PT. Other documentations included skin rashes, number of times of stooling and weight recording.

The primary outcome of the study was rate of fall of bilirubin, which was defined as the difference between maximum bilirubin after enrolment and bilirubin at the end of PT divided by the duration of PT. The secondary outcomes evaluated were duration of PT (from PT initiation to final discontinuation and including interruptions in PT), maternal satisfaction score, nursing satisfaction score, clinical side effects of PT such as hypo/hyperthermia (axillary temperature <36.5/>37.5°C), rash (macular/papular/maculopapular), hypotension (<3rd centile on Zubrow's charts) and increased stooling (> 8 times/day) and biochemical parameters such as fall in calcium, NO and vitamin D. The CFL and LED subgroups were defined a priori.

Statistical analysis: Numerical outcomes such as rate of fall of bilirubin, duration of PT, calcium, NO, vitamin D and maternal and nursing satisfaction score were analyzed by non-parametric tests like Mann–Whitney U-test for independent samples considering their skewed distribution. Categorical outcomes such as hypo/hyperthermia, rash, hypotension and increased stooling were analyzed by Chi-square test or Fisher's exact test. Analysis was done using IBM SPSS Statistics for Windows, Version 21.0 (IBM Corp. NY, USA). Intention-to-treat analysis was performed.

   Results Top

Of a total of 210 neonates who were eligible, 36 were excluded for various reasons and 174 were randomized into either CPT or IPT group. In either group, neonates were stratified to receive either CFL or LED [Figure 1].

The baseline demographic characteristics of the two groups were similar [Table 1]. Analysis of the primary outcome [Table 2] showed that the median rate of fall of bilirubin was higher but non-significant in the CPT group compared to the IPT group (0.16 vs. 0.13 mg/dl/h). The median difference was 0.03 mg/dl/h and the 95 per cent confidence interval (CI) of the median difference ranged from 0.03 to 0.03 mg/dl/h, which was within the pre-defined limits of non-inferiority (Δ=0.04 mg/dl/h).

There was no significant increase in the median duration of PT between the CPT and IPT groups (24 vs. 24 h, P=0.97). Comparison of biochemical parameters between the IPT and CPT groups was done [Table 3]. The mean fall in calcium levels (0.82 vs. 0.96 mg/dl,), or the median rise in NO levels (1 vs. 2 μM/l), or median rise in vitamin D levels (0 vs. 1 ng/ml) in the CPT and IPT groups, respectively, was not significant [Table 2]. Only rash and diarrhoea were noted as clinical side effects in very few cases in either group. CPT and IPT did not show any difference in the proportion of clinical side effects.

Mothers were satisfied in terms of ease of feeding, bonding with the baby and the opportunity to socialize with other mothers during the off time of IPT. However, the nursing staff reported more difficulty in timekeeping and handling of parents in the IPT group. They reported greater satisfaction with CPT compared with IPT [Table 4].

Comparing outcomes stratified according to PT device used, none of the outcomes (primary and secondary) was significantly different between the CPT and IPT groups, when both CFL and LED were used for delivering PT.

   Discussion Top

The results of our study showed that IPT was non-inferior to CPT in decreasing bilirubin levels. Even though CPT resulted in a higher rate of fall of bilirubin, the difference along with the 95 per cent CI was within the pre-defined limits of inferiority. Our study partially concurred with the results of a similar study done in India, where Sachdeva et al[21] found IPT to be not only non-inferior but also more effective than CPT. They used a longer cycling period of 12 h on and then 12 h off IPT protocol to simulate a day care treatment plan. The mean irradiance delivered was higher in our trial (47 μW/cm2/nm). Although Sachdeva et al[21] mentioned that a minimal irradiance of 30 μW/cm2/nm was ensured, but it was difficult to reach irradiance >30 μW/cm2/nm with single CFL devices[22]. It has been postulated that the higher irradiance delivered in our study, in spite of the shorter PT time, has resulted in the higher but non-significant fall in bilirubin in the CPT group.

Other studies comparing IPT and CPT showed varying results, probably because of the different IPT on–off cycles used[23],[24],[25],[26],[27],[28]. However, two trials using shorter IPT cycles, like our trial, showed that IPT was non-inferior to CPT[29],[30]. The higher rate of fall of bilirubin seen in the CPT group, compared to the IPT group, was primarily driven by the results from the LED strata. None of the previous IPT versus CPT trials used LED devices. Although LED devices are potentially more effective than CFL devices because of the higher luminous intensity, irradiance and narrow wavelength band, studies showed that clinical efficacy of LED was only comparable with CFL[22],[30]. Our results were in concordance with other studies using Super LED device with adjusted footprint area[31],[32]. However, the higher efficacy of LED in the CPT group compared to IPT group in CFL and LED subgroups, as suggested by our subgroup analysis, could be an inflation of type 1 error and further adequately powered trials testing this hypothesis would be required.

Comparison of biochemical outcomes in our study showed that the alteration in calcium, vitamin D and NO status was not significantly different between the CPT and IPT groups. It was presumed that the lesser duration of PT received in the IPT group could lead to lesser side effects making IPT a better choice. However, our results proved otherwise, possibly suggesting the presence of hitherto unknown factors that could contribute to these outcomes.

Our presumption was that if IPT was non-inferior to CPT, mothers and nurses might favour IPT, due to the more opportunity to feed and bond with the neonate. However, experts have opined that IPT, despite improving maternal satisfaction, could burden the nurses, especially when short on–off cycles are used[33].

Limitations of our study were that blinding was not possible and duration of PT could not be precisely assessed as bilirubin was measured at 12-hourly intervals only. The baseline bilirubin levels of our study participants were in the moderately hyperbilirubinaemic range, and preterm infants were not enrolled in the study. Hence, our results cannot be extrapolated to infants with severe jaundice and preterm babies.

In conclusion, our results showed that IPT was non-inferior to CPT and could be offered for treating neonatal jaundice, irrespective of the device used. Mothers found it convenient as it provided more opportunities for feeding and fosters mother–infant bonding. CPT caused a higher but non significant rate of fall in bilirubin levels, especially when LED devices were used. Further trials comparing IPT and CPT using LED devices are required to arrive at any final conclusion.

Treatment thresholds for starting PT used in our study were lower than the standard AAP-PT thresholds. Hence, safety should be established at higher values before recommending for practice.

Acknowledgment: Authors acknowledge the support of Ms Vimala Devi, department of Allied Health Sciences, CHRI, for helping in analysing serum samples.

Financial support & sponsorship: None.

Conflicts of Interest: None.

 

   References Top
1.Kemper K, Forsyth B, McCarthy P. Jaundice, terminating breast-feeding, and the vulnerable child. Pediatrics 1989; 84 : 773-8.  Back to cited text no. 1
    2.Elander G, Lindberg T. Hospital routines in infants with hyperbilirubinemia influence the duration of breast feeding. Acta Paediatr Scand 1986; 75 : 708-12.  Back to cited text no. 2
    3.Xiong T, Qu Y, Cambier S, Mu D. The side effects of phototherapy for neonatal jaundice: What do we know? What should we do? Eur J Pediatr 2011; 170 : 1247-55.  Back to cited text no. 3
    4.Aydemir O, Soysaldı E, Kale Y, Kavurt S, Bas AY, Demirel N. Body temperature changes of newborns under fluorescent versus LED phototherapy. Indian J Pediatr 2014; 81 : 751-4.  Back to cited text no. 4
    5.LaRusso J, Wilson J, Ceilley R. Phototherapy-induced Purpuric Eruption in a Neonate. J Clin Aesthet Dermatol 2015; 8 : 46-8.  Back to cited text no. 5
    6.De Curtis M, Guandalini S, Fasano A, Saitta F, Ciccimarra F. Diarrhoea in jaundiced neonates treated with phototherapy: Role of intestinal secretion. Arch Dis Child 1989; 64 : 1161-4.  Back to cited text no. 6
    7.Eghbalian F, Monsef A. Phototherapy-induced hypocalcemia in icteric newborns. Iran J Med Sci 2002; 27: 169-71.  Back to cited text no. 7
    8.Walther FJ, Wu PY, Siassi B. Cardiac output changes in newborns with hyperbilirubinemia treated with phototherapy. Pediatrics 1985; 76 : 918-21.  Back to cited text no. 8
    9.Liu GS, Wu H, Wu BQ, Huang RZ, Zhao LH, Wen Y. Effect of phototherapy on blood endothelin and nitric oxide levels: Clinical significance in preterm infants. World J Pediatr 2008; 4 : 31-5.  Back to cited text no. 9
    10.Weissman A, Berkowitz E, Smolkin T, Blazer S. Effect of phototherapy on neonatal heart rate variability and complexity. Neonatology 2009; 95 : 41-6.  Back to cited text no. 10
    11.Gillies DR, Hay A, Sheltawy MJ, Congdon PJ. Effect of phototherapy on plasma 25(OH)-vitamin D in neonates. Biol Neonate 1984; 45 : 225-7.  Back to cited text no. 11
    12.Staberg B, Christiansen C, Rossing N. Serum vitamin D metabolites in normal subjects after phototherapy. Scand J Clin Lab Invest 1984; 44 : 53-6.  Back to cited text no. 12
    13.Brown AK, McDonagh AF. Phototherapy for neonatal hyperbilirubinemia: Efficacy, mechanism and toxicity. Adv Pediatr 1980; 27 : 341-89.  Back to cited text no. 13
    14.Mreihil K, McDonagh AF, Nakstad B, Hansen TW. Early isomerization of bilirubin in phototherapy of neonatal jaundice. Pediatr Res 2010; 67 : 656-9.  Back to cited text no. 14
    15.Maisels MJ, Baltz RD, Bhutani VK, Newman T, Palmer H, Rosenfeld W, et al. Management of hyperbilirubinemia in the newborn infant 35 or more weeks of gestation. American Academy of Pediatrics Subcommittee on Hyperbilirubinemia. Pediatrics 2004; 114 : 297-316.  Back to cited text no. 15
    16.Olusanya BO, Imam ZO, Mabogunje CA, Emokpae AA, Slusher TM. Maternal satisfaction with a novel filtered-sunlight phototherapy for newborn jaundice in Southwest Nigeria. BMC Pediatr 2014; 14 : 180.  Back to cited text no. 16
    17.Jendrassik L, Grof P. [Vereinfachte photometrische methoden zur bestimmung des blut bilirubins]. Biochem Z. 1938; 297 : 81-9.  Back to cited text no. 17
    18.Giustarini D, Rossi R, Milzani A, Dalle-Donne I. Nitrite and nitrate measurement by Griess reagent in human plasma: evaluation of interferences and standardization. Methods Enzymol 2008; 440 : 361-80.  Back to cited text no. 18
    19.Stern J, Lewis WHP. The colorimetric estimation of calcium in serum with o-cresolphthalein complexone. Clinica Chimica Acta 1957; 2 : 576-80.   Back to cited text no. 19
    20.He CS, Gleeson M, Fraser WD. Measurement of circulating 25-hydroxy vitamin d using three commercial enzyme-linked immunosorbent assay kits with comparison to liquid chromatography: tandem mass spectrometry method. ISRN Nutr 2013; 2013 : 723139.  Back to cited text no. 20
    21.Sachdeva M, Murki S, Oleti TP, Kandraju H. Intermittent versus continuous phototherapy for the treatment of neonatal non-hemolytic moderate hyperbilirubinemia in infants more than 34 weeks of gestational age: A randomized controlled trial. Eur J Pediatr 2015; 174 : 177-81.  Back to cited text no. 21
    22.Kumar P, Murki S, Malik GK, Chawla D, Deorari AK, Karthi N, et al. Light emitting diodes versus compact fluorescent tubes for phototherapy in neonatal jaundice: A multi center randomized controlled trial. Indian Pediatr 2010; 47 : 131-7.  Back to cited text no. 22
    23.Zachman RD. Alternate phototherapy in neonatal hyperbilirubinemia. Biol Neonate 1974; 25 : 283-8.  Back to cited text no. 23
    24.Hodgman JE. Clinical application of phototherapy in neonatal jaundice. Birth Defects Orig Artic Ser 1976; 12 : 3-10.  Back to cited text no. 24
    25.Maurer HM, Shumway CN, Draper DA, Hossaini AA. Controlled trial comparing agar, intermittent phototherapy, and continuous phototherapy for reducing neonatal hyperbilirubinemia. J Pediatr 1973; 82 : 73-6.  Back to cited text no. 25
    26.Vogl TP, Hegyi T, Hiatt IM, Polin RA, Indyk L. Intermediate phototherapy in the treatment of jaundice in the premature infant. J Pediatr 1978; 92 : 627-30.  Back to cited text no. 26
    27.Lau SP, Fung KP. Serum bilirubin kinetics in intermittent phototherapy of physiological jaundice. Arch Dis Child 1984; 59 : 892-4.  Back to cited text no. 27
    28.Niknafs P, Mortazavi AA, Torabinejad MH, Bahman-Bijari B, Niknafs N. Intermittent versus continuous phototherapy for reducing neonatal hyperbilirubinemia. Iran J Pediatr 2008; 18 : 251-6.  Back to cited text no. 28
    29.Khaliq A. Comparison of continuous with intermittent phototherapy in the treatment of neonatal jaundice. J Postgrad Med Inst 2016; 30 : 173-6.  Back to cited text no. 29
    30.Eghbalian F, Sabzian K. Comparison of the effect of intermittent versus continuous phototherapy for reducing neonatal hyperbilirubinemia. J Urmia Univ Med Sci 2012; 23 : 363-7.  Back to cited text no. 30
    31.Martins BM, Carvalho MD, Moreira ME, Lopes JM. Efficacy of new microprocessed phototherapy system with five high intensity light emitting diodes (Super LED). J Pediatr (Rio J) 2007; 83 : 253-8.  Back to cited text no. 31
    32.Reddy TR, Prasad PK, Parakh H, Nagar P. Light-emitting diodes versus compact fluorescent tubes for phototherapy in neonatal jaundice: A randomised control trial. Int J Pediatr Res 2014; 1 : 72-9.  Back to cited text no. 32
    33.Maisels MJ, McDonagh AF. Phototherapy for neonatal jaundice. N Engl J Med 2008; 358 : 920-8.  Back to cited text no. 33
    
  [Figure 1]
 
 
  [Table 1], [Table 2], [Table 3], [Table 4]

 

Top  

Comments (0)

No login
gif